Heating systems consist of a boiler, a furnace, or a heat pump to heat water, steam or air in a central location, such as a furnace room in a home or a mechanical room in a large building. Those systems also include the heat distribution part, whether it is a water circuit or a forced air system with fans & blowers.
In order to ensure that such a heating system is working safely and efficiently various functional checks, adjustments and measurements should be performed on heat pumps, gas-fired systems, oil and solid fuel systems, both during commissioning and at regular intervals.
These include flue gas analysis, differential pressure measurement, leak detection and tightness testing, flow temperature measurement, as well as ambient CO measurement. Also note that combustion analysis is important for engines and other combustion processes whose purpose is not to generate heat. It is required to measure their gas emissions for regulatory compliance reasons and efficiency assessments.
Flue gas
Flue gas
Combustion-based equipment, such as boilers, furnaces or internal combustion engines need to be tightly controlled with regards to environmental and energy regulations. They also have to ensure a perfectly optimized and efficient combustion process over time in order to consume less fuel.
Flue gas analysis with professional combustion analyzers from Sauermann helps make combustion processes more efficient and reduces emissions by optimizing the combustion reaction and processes.
Flue gases released during combustion contain O2, CO2, CO, NOx (oxides of nitrogen), other pollutant gases and soot particles among others. These pollute the environment, have a negative effect on the climate and create numerous health risks for human beings.
Si-CA 130
The Si-CA 130 features a touch-screen display and comes with PC-based management software (in addition to the smartphone app) for more in-depth combustion gas analysis. The three field-replaceable cells and sensors offer expanded measurement capability.
Servicing Heat Pumps
Servicing Heat Pumps
Heat pumps generate heat without any combustion processes and offer greater energy efficiency than even the best condensing boilers. The heating process is based on a refrigerant gas, transporting heat through a phase change cycle. However, most refrigerant gases are not harmless for the environment and usually have a significant cost, so these heat pump systems need to be properly commissioned and maintained.
In order to reliably provide sustainable heat and optimize the heating curve, the heat pumps must be thoroughly checked using suitable measurement technology at regular service and maintenance intervals.
An annual service is also recommended for all heat pumps. This ensures efficient operations, detects any refrigerant gas leaks, and optimizes efficiency to reduce energy costs
Si-RM13
This Si-RM13 combines the sturdiness of the analog manifold with digital smart wireless temperature and pressure probes.
This premium package includes a traditional 2-channel analog manifold body (by-pass type) with flexible hoses and a durable block made of anodised aluminum.
Differential Pressure
Differential Pressure
When you carry out servicing work on residential heating systems, the differential pressure measurement is part of the standard repertoire. This includes:
- Measurement of gas pressure and static pressure of a boiler
- Draft pressure: pressure measurement in the combustion chamber or exhaust stack/flue to ensure the combustion gases safely and properly exit the combustion equipment
The measurement of gas flow and static gas pressure in the system is especially important, because the burner can only operate well at a specified flow pressure range. Outside this range, explosive flame formation can occur. The consequences are malfunctions or even breakdown of the heating system. For this reason, the acquisition of a reliable, easy-to-operate differential pressure measuring instrument is essential.
Temperature
Temperature
In order for a heating system to work efficiently and distribute heat energy as uniformly as possible, temperature measurement is crucial. At Sauermann you will find temperature measuring instruments for these important heating measurements, directly performed on heating equipment or in a room’s ambient air
KIRAY 100
The Kimo KIRAY 100 infrared thermometer with a dual laser sighting is a key instrument to diagnose, inspect and check any temperature, with the advantage of using “no-contact” technology. It has a range from -50 to +800 °C.
An infrared thermometer measures surface temperatures of hot objects that are dangerous or difficult to access.
Tightness Testing and Gas Leak Detection
Tightness Testing and Gas Leak Detection
Both heat pumps and combustion-based heating systems can severely suffer from refrigerant and combustible gas leaks. Most refrigerants are powerful greenhouse gases that can seriously harm the environment and sometimes can be explosive (such as R32). Combustible gases leaks can raise safety concerns, be explosion hazards, and waste valuable fuel. Thus, it is utterly important to be able to easily locate any leak in order to quickly repair or replace the impacted portion of the gas circuit.
Searching for and finding gas leaks can be very difficult. Fast professional leakage sniffers are essential to locate the slightest leaks precisely and quickly in a gas circuit.
Products and accessories
Testimonials
Si-CA 030 / 130 / 230
These new Sauermann combustion analyzers are now the best on the market. No one can match these features and simple user interface. Bravo Sauermann!
Si-CA 230
Sauermann's analyzers are handy and compact. The app can easily connect the device to a smartphone or a laptop, even with a high range! We are very satisfied with these new instruments!
Si-CA 030 / 130 / 230
Its intuitive menus as well as operation is among the best I have seen for a long time.
Nice to see a product that redefines the marketplace instead of saying "me too".
The layout, obvious use of high-quality parts, and form factor are all top notch and exceed others at the price points.
Si-CA 130
A very fast analysis done in just 2 minutes.
Si-CA 030 / 130 / 230
These analyzers give us a chance to provide an analyzer line that has no weaknesses, and that app is amazing. Our customers love them.
Si-CA 030
This analyzer has a nice color display and is very lightweight.
Si-CA 030 / 130 / 230
These new analyzers have just put the rest of the industry on notice. Buy them – you won’t be disappointed.
Si-CA 030 / 130 / 230
These new analyzers are best in class and the best that you can buy. Sauermann really thought of both the end user and the distributor.
Si-CA 030 / 130 / 230
These new combustion analyzers are excellent. Nice to see a company has finally given us the features we have been asking for.
Videos
Blog posts
Application notes
Over 800 m2 of laboratory space
Our experts provide maintenance, adjustment and calibration services for our measurement instruments.
After-sales service
Our technicians maintain and repair your devices right where they’re made.
Over 20 patents
Including our oscillating piston pump technology and the foldable frame system found on our DBM 620 air flow meter.