solution cabin paint

Personal safety and quality of finish

The spray booth is an essential piece of equipment for protecting operators against the risks associated with inhaling solvent particles and vapours. Measurements of air pressure, velocity and flow rate enable the effectiveness of its ventilation to be checked.

A safe industrial working environment requires strict monitoring of ventilation and air filtration within these cabins. Sauermann offers all the measurement solutions needed to guarantee precise control of air parameters to ensure the safety and quality of operations.

Parameters to be monitored

  • Velocity

  • Pressure

  • Airflow

Cabin Ventilation

Cabin Ventilation

The NF EN 16985 standard sets out strict requirements for ventilation efficiency, which goes some way to ensuring the safety of paint booths. Propeller or hot-wire anemometers must be of the highest measurement accuracy, with sensitivity adapted to low air speeds.

A homogeneous, unpolluted air flow must surround the operator to protect him. The air flow must be sustained. Moreover, air recycling is prohibited. Kimo Class 110 measuring instruments are accurate and reliable enough to monitor these critical parameters in paint booths.

read more about VT 110 / VT 115

VT 110 / VT 115

Hotwire thermo-anemometer

Kimo’s VT 110 / 115 is perfect for measuring airflow, air velocity and temperature with its hot wire probe.

read more about LV 130

LV 130

Thermo-anemometer with integrated vane probe

The Kimo LV 130 precisely measures air velocity and ambient temperature with a rotating vane probe.

solution cabin paint
Target Values

Target Values

Horizontally ventilated cabins require an average air velocity greater than 0.5 m/s, with no measuring point below 0.4 m/s. Vertical cabins require an average air speed of at least 0.30 m/s at 1 metre from the floor, with no point below 0.25 m/s.

Accurate assessment of the average velocity requires measurements at a minimum of 9 points evenly distributed over the cross-section of the grille. The final average velocity value is calculated by averaging the velocities measured in each defined zone, thus guaranteeing good diffusion of the airflow in the cabin.

read more about AMI 310

AMI 310

Multifunction

Kimo’s AMI 310 measures simultaneous parameters including pressure, temperature (Pt100 and thermocouple), humidity, air quality (CO/CO2), air velocity, airflow (vane probes and hotwire), and tachometry.

read more about VT 210

VT 210

Thermo-hygrometer-anemometer

Specially designed for the control of ventilation systems, the VT 210 allows users to measure the air velocity, the airflow and the temperature in ducts.

read more about MP 210

MP 210

Micromanometer

Kimo’s MP 210 micromanometer measures pressure, air velocity, airflow, temperature, tachometry, gas leak and carbon monoxide (up to 6 simultaneous measurements).

solution cabin paint
Air Filtration

Air Filtration

Filtration of polluted air is required to protect the immediate environment of paint booths. Differential pressure sensors continuously monitor the clogging of the air filters, so that they can be replaced at optimum preventive intervals.

The CP 25 liquid column manometer is specially designed for visual monitoring of filter clogging in paint booths. An electronic sensor like the PST-12 also provides visual and audio alarms in the event of filter saturation, and the CP 110 will transmit its measurements to a monitoring system.

read more about CP 25

CP 25

Inclined liquid column manometer

Kimo's CP 25 inclined liquid column manometer measures slight variations in pressure, depression or differential pressure of air or gas. It is specially designed for checking clogging of filters in painting booths.

read more about PST

PST

Pressostat

A manostat is a pressure gauge which has a switch inside its casing. At a selected pressure the switch activates an electrical contact and stops the machine on which it is wired.

Kimo’s PST is used to control pressure.

read more about CP 110

CP 110

Differential pressure transmitter

The CP 111 / 112 / 113 measure differential pressure from -100/+100 Pa to -10,000/+10,000 Pa (according to models).

The CP 114 / 115 measures pressure from -500/+500 mbar to -2,000/+2,000 mbar.

solution cabin paint
Metrological services

Metrological services

Accurate and reliable measurements are crucial to guaranteeing the reliability and energy efficiency of paint booths. Rigorous metrological monitoring is essential to prevent any drift in measuring equipment, whether fixed or portable.

In its French laboratories, Sauermann offers a complete verification, calibration, adjustment and certification service for anemometers from 0.15 m/s, as well as for pressure, temperature, humidity and air flow to optimise the performance of ventilation systems.

solution cabin paint
France

In-House

Our two main factories
Our customer service
Our metrology laboratories
Our Research & Development team

45 years of experience

45 years of experience

For over 45 years, the Sauermann Group has been designing, manufacturing and marketing products and services dedicated to the HVACR and industrial markets.