The easy-to-use HVACR measuring instruments range
Sauermann’s new range of measuring instruments offers its 45 years of metrological expertise to distributors in the HVACR sector.
Sauermann offers 8 reliable and precise instruments designed to quickly check the functionality of HVACR systems.
Full spectrum HVAC-R management
Air parameters measurement
Instrument | Heating | Ventilation | Climatisation | Refrigeration | |
---|---|---|---|---|---|
New Si-VH3Hotwire thermo-anemometer |
Air-conditioning circuit | ||||
- Measure air flow in ducts | |||||
Tip: Input the duct cross-section in the app to calculate average air flow rate in addition to air velocity. Use Hotwire instead of a vane for low speed air flows, or laminar air flows. |
|||||
Si-RM3 Manifold |
Heat pumps | Air-conditioning units | Refrigerators, freezers | ||
- Measure superheat and sub-cooling of the refrigerant gas circuit - Measure high side and low side pressure - Calculate condensation and evaporation temperatures for 126 different gases |
|||||
Tip: Essential when repairing a refrigerant gas leak (checking for draining and clogging, and re-commissioning). | |||||
Si-PM3 Digital differential pressure manometer |
Gas-fired boilers | Ventilation circuit | |||
- Measure pressure at the gas inlet valve - Measure pressure drop (draft) at the flue |
- Check filter clogging - Measure extractor fan pressure and air flow rate |
||||
Tip: Use the smartphone app to automatically calculate air flow and air velocity in a duct. Connect the manometer at the pressure element and enter the coefficient. You can also connect a Pitot tube and enter the coefficient and duct dimensions. | |||||
Si-TT3 Dual input thermocouple thermometer |
Water heaters | Multifunction | Refrigerators, freezers | ||
- Compare the water temperature in the boiler outlet and return pipes. |
- Ambient air temperature - Air temperature in the ducts - Temperature in domestic hot water systems |
- Measure superheat and sub-cooling of the refrigerant gas circuit. | |||
Tip: The smartphone app records the temperatures, and delta temperatures, over time to see that installation is working correctly. Can be viewed as a table or a graph. | |||||
Si-TI3 Infrared thermometer |
Radiators | ||||
- Measure radiator hot and cold spots to determine if venting is required. | |||||
Tip: Vastly improves speed and convenience (measurements delivered remotely in real time). Can measure ambient temperature (via app). Quickly see if you have overheating sources, for example on an electric installation. Affix a black strip on non-black surfaces. Adjust the emissivity of the surface (as per the manual) from 0.10 to 1.00 for accurate measurement. |
|||||
Si-HH3 Thermo-hygrometer |
Ventilation | ||||
- Measure ambient air temperature and relative humidity. | |||||
Tip: Extreme relative humidity values (too high or too low) can pose hazards (allergies, germs, dust, mould, etc.). The app shows psychrometric parameters, such as dew point and wet temperature. | |||||
Si-VV3 Vane thermo-anemometer |
Air-conditioning circuit | ||||
Measure air flow through system inlet and outlet air vents. | |||||
Tip: Input the duct cross-section in the app to calculate average air flow rate in addition to air velocity. |
Backlit LCD screen
Long-battery life
Magnetic backing for easy fixing
Carrying bag
Calculated values on mobile App
Reports creation on mobile App
Mobile App
The Sauermann Si-HVACR Measurement MobileApp allows to view and record measurements in real-time.
- Easily view different parameters
- Browse saved measurements history and data graphs (average, min & max values, etc.)
- Create reports (PDF, CSV or XML format) and add up to four (4) photos
Leak detection
Heating | Ventilation | Climatisation | Refrigeration | |
---|---|---|---|---|
Si-CD3 Gas leak detector |
Gas-fired boilers | |||
Detects leaks of combustible gases upstream of the boiler, at the inlet and inside the unit. | ||||
Tip: A flexible probe keeps the device’s sensor in contact with gas pipes in even the hardest-to-reach places. Pay special attention to joints in the circuit. Follow the manufacturer’s recommendations for replacing the sensor. |
||||
Si-RD3 Refrigerant leak detector |
Heat pumps | Air-conditioning units | Refrigerators, freezers | |
Detects refrigerant leaks in every part of the cooling circuit. | ||||
Tip: A flexible probe keeps the device’s sensor in contact with gas pipes in even the hardest-to-reach places. Pay special attention to joints in the circuit. |
Adjustable audio and visual alarm
30 cm flexible probe
Very high sensitivity