Accessibility links Skip to main content

Refrigeration

Condensate pumps for refrigeration: choose an ultra-flat pump for supermarket display cabinets and/or a tank pump for industrial refrigeration displays. The Si-1931 fits under very low cabinets and comes with the Gel-Clear anti-biofilm tablet. The Si-1850 tank pump offers flow rates up to 1,100 l/h.

Do you have questions about Refrigerations ?

Open display cabinets produce abundant condensation. They are often placed in the middle of the store, so a powerful pump is needed to evacuate the condensate over long distances. The cabinets run 24 hours a day, 365 days a year, and the condensate carries particles and organic matter that can clog the drainage circuit. A failure puts the cold chain at risk and creates a slip hazard in the aisle.

  • Si-1931: ultraflat pump designed to handle condensate from supermarket refrigerated display cabinets, supplied with a Gel Clear tablet against biofilm. It is only 8 cm high, made entirely of stainless steel, and reaches 700 l/h with a discharge head of 24.6 m.

  • Si-1805 (bare ends): centrifugal tank pump for air conditioning and refrigerated display cabinets.

  • Si-1850: large tank pump, up to 1100 l/h, suitable for industrial refrigeration displays. It tolerates charged, high-temperature condensate.

  • Si-83: compact tank pump, also featured for refrigeration applications.

See each product page for the full specifications.

Puddles are most often overflows from a condensate drainage system blocked by pollution (particles, algae, biofilm, sludge). The most common cause is biofilm, which often clogs the drainage tubes upstream of the pump. The condensate must reach the pump reservoir: a pump that resists biofilm is not enough on its own.

Use a non-aggressive anti-biofilm solution such as the Gel Clear tablet supplied with the Si-1931. One tablet can keep the condensate pipes free of blockages for up to a year. The tablet is replaced every six months or every year, depending on climate and cabinet size, and can be inserted while the unit is running.

The tablet is certified non-corrosive for metal and non-aggressive for condensate pumps, it is fully water-soluble, and the formula is approved by NSF International for use in food preparation zones. The Gel Clear safety data sheet can be downloaded from the Si-1931 product page.

Once biofilm has been spotted, it is already too late: the chilled food aisle may have to be closed, the cooling unit switched off and the system deep-cleaned, sometimes for several days. According to Sauermann, 40% of maintenance call-outs on supermarket refrigerated units relate to biofilm, and the Si-1931 with Gel Clear tablet reduces condensate leaks in chilled and frozen food aisles by 95%. A field study by a major Australian retailer showed significant savings on annual maintenance costs.

These pumps should require infrequent maintenance, and be designed to speed up the work of HVACR technicians: connections to the drain tubes that disconnect easily, a pump that opens quickly and preferably without tools, and easy access to the pump core, the filter and the tank. With the Gel Clear solution, maintenance is limited to quick, routine tasks such as replacing the tablet every six months or every year.

The choice depends on the system in which the pump will be installed:

  • Type of unit: split, ducted, floor-standing, cassette, boiler, refrigerated display case, etc.

  • Power of the heating or cooling system, which determines the quantity of condensate. Climate also matters: in a humid climate the quantity of condensate can be double that of a dry climate.

  • Nature of the condensate: polluted and greasy in a kitchen or hairdresser's, acidic for boilers.

  • Available space, which determines the shape and size of the pump, and where it will be placed (next to, below, inside or remotely above the unit).

  • Type of room, which determines the trade-off between noise and power.

  • Maintenance: not all pumps are easy to detach and clean.

We recommend calling in a professional about once a year, and more often when the pump is exposed to air loaded with particles (flour in a bakery, for example). Check your air conditioner before summer: the mini pump can even foul over winter, when the unit is in heating mode and the pump is out of use.

For a mini pump, clean the reservoir and filter every 3 to 6 months and inspect the wiring and tubing for wear or leaks. The detection unit should be cleaned at the beginning of the season and regularly if the system is used all year round. You can also inspect the detection system and the (often transparent) drain tubes for dirt.

Sauermann condensate removal pumps are covered by a 36-month guarantee. Other Sauermann Industrie products are covered by a 12-month contractual guarantee, and manifolds and instruments in the distribution range by a 24-month guarantee. The guarantee periods start from the date of the invoice. See the Warranty page for the full conditions.

The guarantee does not apply to damage caused by improper use, improper monitoring or maintenance, normal wear and tear or force majeure, nor to consumables and wear parts. It is limited to a credit note for the price paid or a like-for-like replacement. The guarantee should first be claimed from the installer or distributor from whom the product was purchased.

Sauermann pumps are sold through distributors. Use the interactive "Where to buy" map to find your nearest Sauermann condensate pump distributor or to ask about prices.

For any other after-sales question about our pumps, contact your distributor. For calibration, repair, on-site intervention, technical assistance or document requests on instruments, use the Customer Portal: sign in or create your account to access our service offers. You can also use the Contact page of the website.

contact